Model |
C-2 |
C-10 |
C-16 |
C-24 |
C-36 |
C-61 |
Detector |
1/1.2” |
4/3” |
4/3” |
APS-C |
Full Size |
Full Size |
Total Pixel (million) |
2.28 |
11.20 |
16.21 |
24.34 |
36.17 |
60.92 |
Effective Pixels |
1900*1200 |
4100*2732 |
4634*3500 |
6228*4156 |
7338*4930 |
9560*6372 |
Pixel Size |
5.68μm |
4.63μm |
3.8μm |
3.76μm |
4.88μm |
3.76μm |
Cooled System |
Two stage TEC.(Typical -45 below Ambient) |
|||||
Dynamic Range |
>1000000:1(Multiple exposure) |
|||||
Pixel Depth |
16bits |
|||||
Exposure Time |
16uSec to 60Sec |
|||||
Measurement Function |
Luminance,CIE1931 & CIE1976,CCT,Dominant wavelength |
|||||
Luminance |
Measurement range |
0.0001 to 100,000cd/m^2 |
||||
Accuracy*¹ |
±3% |
|||||
Repeatability(δ)*¹ |
±0.5% |
|||||
Chromaticity |
Illuminant A*¹ |
±0.002 |
||||
LEDLight Source*¹ |
±0.002 |
|||||
Standard LCD*¹ |
±0.002 |
|||||
Other Uncorrected Source*¹ |
±0.01 |
|||||
Repeatability(δ)*¹ |
±0.0003 |
|||||
Lens |
24mm、28mm、35mm、50mm、100mm Finterface Lens |
|||||
Dimension |
240*150*160mm(L*W*H) |
|||||
Interface |
LAN |
|||||
Operation Temperature |
5 to 50°C |
|||||
Input Voltage |
ACAdapter |
Lens |
Distance |
C-2 |
C-10 |
C-16 |
C-24 |
C-36 |
C-61 |
24mm |
300mm |
141*88 |
241*162 |
221*167 |
294*196 |
448*305 |
448*305 |
500mm |
234*146 |
402*270 |
369*279 |
490*327 |
746*508 |
746*508 |
|
1000mm |
469*292 |
803*540 |
737*558 |
979*654 |
1492*1017 |
1492*1017 |
|
1500mm |
703*438 |
1205*809 |
1106*836 |
1469*981 |
2238*1525 |
2238*1525 |
|
2000mm |
938*583 |
1607*1079 |
1474*1115 |
1958*1308 |
2984*2033 |
2984*2033 |
|
28mm |
300mm |
121*75 |
207*139 |
190*143 |
252*168 |
384*258 |
384*258 |
500mm |
201*125 |
344*231 |
316*239 |
420*280 |
639*430 |
639*430 |
|
1000mm |
402*250 |
689*463 |
632*478 |
839*561 |
1279*861 |
1279*861 |
|
1500mm |
603*375 |
1033*694 |
948*717 |
1259*841 |
1918*1291 |
1918*1291 |
|
2000mm |
804*500 |
1377*924 |
1264*956 |
1679*1121 |
2558*1721 |
2558*1721 |
|
35mm |
300mm |
96*60 |
165*111 |
152*115 |
201*135 |
307*207 |
307*207 |
500mm |
161*100 |
275*185 |
253*191 |
336*224 |
512*344 |
512*344 |
|
1000mm |
321*200 |
551*370 |
505*382 |
671*449 |
1023*689 |
1023*689 |
|
1500mm |
482*300 |
826*555 |
758*573 |
1007*673 |
1535*1033 |
1535*1033 |
|
2000mm |
643*400 |
1102*740 |
1101*765 |
1343*897 |
2046*1377 |
2046*1377 |
|
50mm |
300mm |
68*42 |
116*78 |
106*80 |
141*94 |
215*145 |
215*145 |
500mm |
113*70 |
193*130 |
177*134 |
235*157 |
358*241 |
358*241 |
|
1000mm |
225*140 |
386*259 |
354*268 |
470*314 |
716*482 |
716*482 |
|
1500mm |
338*210 |
578*389 |
531*401 |
705*471 |
1074*723 |
1074*723 |
|
2000mm |
450*280 |
771*518 |
708*535 |
940*628 |
1432*964 |
1432*964 |
Séparateur de faisceaux intégré, relié à un module d'analyse spectrale intégré optionnel, avec fonction de Radiomètre Spectral à point unique; étalonnage automatique pour augmenter la précision du colorimètre d'imagerie au niveau du Radiomètre Spectral; et fournir des données d'analyse spectrale de rayonnement spectral.Spécification du colorimètre d'imagerie
Wavelength Rang |
350-1100nm |
|
Spectrum Resolution |
1nm |
|
Signal to noise ratio |
150:1 |
|
AD |
16bits |
|
Exposure Time |
3mSec~24Sec |
|
Measurement Function |
Luminance,CIE1931 & CIE1976,CCT,Dominant wavelength |
|
Luminance |
Measurement range |
0.1 to 100,000cd/m2 |
Accuracy*¹ |
±3% |
|
Repeatability(σ)*¹ |
±0.5% |
|
Chromaticity |
Standard Illuminant A |
±0.002 |
Repeatability(σ)*¹ |
±0.0003 |
|
Interface |
USB |
* mesure de la luminosité et de la colorimétrie dans des conditions de nuages de lumière (à l'aide d'une source lumineuse standard de 1000cd / M 2 , rétroéclairage LED, affichage LCD 6500k).
* Les spécifications et l'apparence peuvent être modifiées sans préavis.